China ISC Industry Electronic Weighing Belt Scale Suppliers - High Precision Conveyor Weighing Factory Equipment
Features
- Using sealed bearing as the support, accurate and stable force transmission, fast zero return.
- Solid weighing bridge and impact resistance, particularly suitable for work in harsh conditions.
- Non-distortion of the scale body and stable measurement accuracy.
- No moving parts and less maintenance.
- Various calibration methods and multiple output interfaces to meet various control requirements.
- Turn on the power required for each metering unit.
- Eliminate all potential factors inside and outside the measuring scale that may cause unstable operation of the measuring scale. Ensure that there are no foreign objects in the funnel and that the measuring scale is not disturbed by other equipment during operation. If there is material in the hopper, please touch the "Empty Feed Scale" button.
- The equipment should be peeled after its first use or disassembly. Peeling can only be carried out when there is no material in the funnel. Peeling is strictly prohibited during normal operation.
- The upper and lower limits of the feed should not be set too high, otherwise the material will overflow. Nor should they be set too low, otherwise frequent feeding will cause unstable measurement and weighing operations. The lower limit of the feed should not be set too low, otherwise the drive command will be too high, affecting the feeding accuracy.
- Open the feed valve of the bulk weighing scale and inject the material into the funnel.
- Inspection:
- Set the initial feed volume, check the drive command, and check the time. The initial value of the feed volume should be greater than 0. If it equals 0, an error alarm for the feed volume will occur and the metering scale cannot start.
- Before inspection, the weighing scale should be operated to fill the feeding screw and the sleeve with materials.
- Press the "Start Inspection" button to conduct the inspection.
- Check the larger feed volume to determine whether the larger flow rate and weighing of the production line are suitable.
- Notify the skilled personnel to set the proportion of the formula and do not change it at will.
- When the main machine speed of the bulk weighing scale reaches the set value, first set the feed volume, then start weighing 1# in sequence. After the material flows out of the machine head, start weighing 2# in sequence. Note that when the main machine starts, the side feeding motor should be connected simultaneously.
Technical Parameters
| NO. | Model | Adaptive belt width (mm) |
Accuracy (%) |
Weighting capacity (T/h) |
Belt inclination | The weighing sensor (Branch) |
Weighing support roller (Branch) |
Voltage (V) |
|---|---|---|---|---|---|---|---|---|
| 1 | ICS-5 | 500 | ±0.125 | 1-2000 | ≤17° | 2 | 2 | 220±10% |
| 2 | ICS-6.5 | 650 | 1-2000 | ≤17° | 2 | 2 | ||
| 3 | ICS-8 | 800 | 1-2000 | ≤17° | 2 | 2 | ||
| 4 | ICS-10 | 1000 | 1-2000 | ≤17° | 2 | 2 | ||
| 5 | ICS-12 | 1200 | 1-2000 | ≤17° | 2 | 2 | ||
| 6 | ICS-14 | 1400 | 1-2000 | ≤17° | 2 | 2 |
Application
It can be widely used in building material, metallurgy, electricity, chemicals, coal, mine, port and other industries.
Frequently Asked Questions (FAQ)
What are the main features of the bulk weighing scale?
The bulk weighing scale features accurate and stable force transmission using a sealed bearing, a solid weighing bridge resistant to impact, a non-distortion scale body, zero moving parts for less maintenance, and supports various calibration methods and multiple output interfaces.
How do I prepare the measuring scale before start-up?
Before starting, turn on the required power, eliminate potential internal and external factors that could cause instability, ensure no foreign objects are in the funnel, and confirm no other equipment will cause disturbances. Touch the "Empty Feed Scale" button if there is material in the hopper.
When should the peeling process be carried out?
Peeling should only be conducted after its first use or disassembly, and strictly when there is no material in the funnel. It is strictly prohibited to perform peeling during normal operation.
What happens if the initial feed volume is set to zero?
The initial value of the feed volume must be greater than 0. If it equals 0, an error alarm for the feed volume will occur, and the metering scale will be unable to start.
How should the upper and lower limits of the feed be configured?
The limits should not be set too high to prevent material overflow, nor too low, as frequent feeding causes unstable measurement operations and high drive commands, which negatively affect feeding accuracy.
In which industries can this bulk weighing scale be applied?
The equipment is widely used across various industries, including building materials, metallurgy, electricity, chemicals, coal, mining, and port facilities.






